Product Details:
Model | DIPC117 |
Automation Type | Semi-Automatic |
Color | Grey |
Warranty | 2 year |
Brand | DIDAC |
Material | Stainless Steel |
Current | 0-200 W |
Floor Area | No |
Ball Valve | No |
Bend | No |
Control Panel | Yes |
Elbow | No |
Gate Valve | No |
Stop Watch | No |
Test Type | No |
Water Circulation | Yes |
A combination of refined oil, water and air enters the vessel, the flow is directed to the spherical end of the vessel where primary separation occurs and then flows through the vessel where it meets the coalescer. At the secondary separating section, the fluids are allowed to slow down and separate by gravity. The water being the heaviest in gravity stays at the bottom while the oil floats on top and the gas occupies the void space in the vessel.
External Capabilities:
Additional Information:
Product Details:
Brand | DIDAC |
Material | Stainless steel |
Operating Frequency | 45deg c |
Floor Area | NO |
Two Spring Balances | 2 |
Current | 12v |
Frame | Horizontal |
Accuracy | 75 |
Control Panel | yes |
Additional Information:
Product Details:
Brand | DIDAC |
Material | Stainless steel |
Floor Area | No |
Ball Valve | No |
Bend | No |
Control Panel | Yes |
Elbow | No |
Gate Valve | No |
Stop Watch | No |
Test Type | No |
Water Circulation | Yes |
An arrangement of up to date integrated circuits is used to simulate boiler pressure and burner control together with the sensing and control systems associated with modern boiler systems. The simulated boiler itself is constructed from a clear acrylic tank and thus the demonstration unit provides a clear visual appreciation of the operating characteristics of the various level controls i.e. float operated magnetic, reed or electronic system using electrode sensors. The operation of these level sensing devices can readily be investigated since they may be removed from the Demonstration Unit, dismantled and re-assembled, without the attendant problems which would occur on an operational boiler. These systems would not normally all be fitted in the same boiler but are included in this unit to give the student an appreciation of the characteristics of each system. Conversion of water from the boiler into steam is simulated so that the level sensors need to operate as in a true Boiler system. A Boiler Water Gauge is fitted to the Boiler Drum so that possible misuse of this item can be demonstrated clearly and safely. This Gauge can also be used to demonstrate the method of changing a ‘sight glass’ for such a gauge under simulated working conditions, a circumstance which can be ‘safely’ taught on this Demonstration Unit.
Experimental Capability:
Additional Information:
Product Details:
Power (W) | AC 380 V, 7 50 Hz |
Automation Grade | Semi-Automatic |
Brand | DIDAC |
Material | Stainless steel |
Floor Area | No |
Ball Valve | No |
Bend | No |
Control Panel | Yes |
Dimensions | 1200 x 800 x 1500 mm ( L x W x H ) |
Mechatronics Trainer is composed by the aluminum rail training station, mechanical components of the typical electromechanical integration equipment, PLC module unit, touch screen module unit, the inverter module unit, the button module unit, the power module unit, simulation production equipment training module, terminal blocks and a variety of sensors and other components. The overall structure is open and removable. The training equipment is used for the assembly of mechanical components according to the mechanical parts of existing training equipment to assemble production training equipment, or can be added mechanical components to assemble other production training equipment, so that the whole device can be flexibly assembled into an electromechanical integration device with the simulated production function according to teaching and competition requirements. The modules use standard structure and the drawer-in module holder, interchangeable; you can determine the module content in accordance with principles of the production features and integration with learning functions, so as to easily select the desired module during teaching or competition. The system includes multiple technologies such as motor drives, mechanical drive, pneumatic, touch screen control, programmable controllers, sensors, frequency speed regulation and many other technologies involved in electromechanical integration professional, which provides students a typical comprehensive environment so that students can get a comprehensive understanding of, consolidate, comprehensively train and practically apply the learned basic knowledge of single professional in the past.
Specifications:
Additional Information:
Product Details:
Brand | DIDAC |
Model | DIAT049 |
Material | Stainless steeel |
Usage | Industrial |
Capacity | 1.5 Ltrs |
Floor Area | No |
Ball Valve | No |
Bend | No |
Control Panel | Yes |
Elbow | No |
Gate Valve | No |
Stop Watch | No |
Test Type | No |
Water Circulation | Yes |
The setup consists of a process tank in which compressed air enters through a Pneumatic Control Valve. The pressure transmitter is fitted on the process tank. The air pressure in process tank is sensed by the transmitter and communicated to the digital indicating controller. This measured variable is compared with the set point by controller and output is generated and given to i/p converter, which in turn supply the 3- 15 psig pressure to vary the opening of the pneumatic control valve to eliminate the error observed. As the opening of pneumatic control valve varies, the pressure in the process tank gets effected. This process goes on until the set point target is achieved. A ball valve is also provided in the process tank to disturb the system and to observe the effect of disturbance. These units along with necessary piping are supported in a well- designed housing and are fixed on base plate.The present set-up is completely computerized controlled. The digital indicating controller has a facility to interface the system with computer which enables to change the PID parameters using computer.
Technical Data:
Additional Information:
Product Details:
Brand | DIDAC |
Model | DIPE39 |
Material | Stainless steeel |
Usage | Laboratory |
Floor Area | No |
Electricity Supply | 220 240V 1ph 50Hz at 10A |
Frequency | 0 to 105 deg C |
Ball Valve | No |
Bend | No |
Elbow | No |
Gate Valve | No |
Stop Watch | No |
Water Circulation | Yes |
Features:
Additional Information:
Product Details:
Model | DIPE21 |
Material | Stainless Steel |
Automation Type | Semi-Automatic |
Color | Grey |
Phase | Single |
Warranty | 2 years |
Brand | DIDAC |
Features:
Technical Data:
Line recorder:
Controller:
Additional Information:
Product Details:
Brand | DIDAC |
Model | DIPE38 |
Material | Stainless steeel |
Usage | Laboratory |
Operating Frequency | 0 to 105 Deg C |
Capacity | 7 lt |
Ball Valve | No |
Bend | No |
Control Panel | Yes |
Gate Valve | No |
Stop Watch | No |
Test Type | No |
Features:
Technical Data:
Centrifugal pump:
Level-controlled tank:
Additional Information:
Product Details:
Application | Industrial |
Brand | DIDAC |
Material | Stainless Steel |
Operating Frequency | 0 to 105 Deg C |
Model Number | DIPE24 |
Floor Area | No |
Ball Valve | No |
Bend | No |
Control Panel | Yes |
Elbow | No |
Gate Valve | No |
Stop Watch | No |
Test Type | No |
Water Circulation | Yes |
Features:
Technical Data:
Fan:
Line recorder:
Additional Information:
Product Details:
Usage | Industrial |
Brand | DIDAC |
Capacity | 20l |
Color | Gray |
Material | Stainless Steel |
Floor Area | No |
Application | Industrial |
Vertical Arm | No |
Ball Valve | No |
Bend | No |
Control Panel | Yes |
Stop Watch | No |
Pressure Max | 20 Bar |
Test Type | No |
Water Circulation | Yes |
Warranty | 2 years |
Additional Information:
Product Details:
Brand | DIDAC |
Material | Stainless Steel |
Frame | Horizontal |
Usage | Industrial |
Floor Area | No |
Ball Valve | No |
Bend | No |
Control Panel | Yes |
Elbow | No |
Stop Watch | No |
Test Type | No |
Water Circulation | Yes |
We have carved a niche amongst the leading firms in the market and are into presenting an extensive quality range of PLC Trainer to clients. This PLC Trainer is valued amongst our clients due to its features like optimum performance and user friendly. Offered products are used for study of working of Programmable Logic Controllers.
Features:
Additional Information:
Product Details:
Automatic Grade | Semi-Automatic |
Usage | Industrial |
Brand | DIDAC |
Condition | New |
Color | Gray |
Material | Stainless steel |
Floor Area | No |
Ball Valve | No |
Bend | No |
Control Panel | Yes |
Elbow | No |
This trainer Very useful to study the Pneumatic Trainer Components like FRL, Pilot valve, cylinder etc. Students can makes Design and verifies the circuit’s pneumatic level operation using this kit.
Additional Information:
Product Details:
Brand | DIDAC |
Model | DIPC118 |
Material | Stainless steeel |
Usage | Industrial |
Floor Area | No |
Ball Valve | No |
Bend | No |
Control Panel | Yes |
Elbow | No |
Gate Valve | No |
Stop Watch | No |
Test Type | No |
Water Circulation | Yes |
Features:
Additional Information:
3.6/5